Parkinson's Disease Tulip


advertisement
Reply
 
Thread Tools Display Modes
Old 06-04-2007, 09:59 PM #1
Stitcher's Avatar
Stitcher Stitcher is offline
Magnate
 
Join Date: Aug 2006
Posts: 2,136
15 yr Member
Stitcher Stitcher is offline
Magnate
Stitcher's Avatar
 
Join Date: Aug 2006
Posts: 2,136
15 yr Member
Default A first: Simultaneous PET/MR images of the brain debut, increase molecular imaging ca

A first: Simultaneous PET/MR images of the brain debut, increase molecular imaging capabilities

Public release date: 4-Jun-2007
http://www.eurekalert.org/pub_releas...-afs052707.php

Researchers from the Universities of Tuebingen and Tennessee and Siemens Medical Solutions provide world’s first simultaneous positron emission tomography and magnetic resonance images of the brain at SNM's 54th Annual Meeting June 2–6 in Washington, D.C.

WASHINGTON, D.C.—The world's first PET/MR images of the human brain—taken simultaneously by positron emission tomography (PET) imaging and magnetic resonance (MR)—debuted during the 54th Annual Meeting of SNM, the world's largest society for molecular imaging and nuclear medicine professionals, June 2–6 in Washington, D.C.

"Here at SNM's Annual Meeting, we are showing the first simultaneously acquired PET/MR images of the human brain," noted Bernd J. Pichler, associate professor and head of the Laboratory for Preclinical Imaging and Imaging Technology in the Department of Radiology at the University of Tuebingen in Germany. "PET/MR, acquired in one measurement, presents a tremendous leap forward in imaging capabilities. PET/MR—acquired in one measurement—has the potential to become the imaging modality of choice for neurological studies, certain forms of cancer, stroke and the emerging study of stem cell therapy," he added. "We expect that PET/MR will open new doors in understanding the pathologies and progression of various neurological disorders like Alzheimer's, Parkinson's, epilepsy, depression and schizophrenia," he emphasized.

"The feasibility of simultaneous PET/MR imaging in humans opens new potentials in the emerging field of molecular imaging. Our data prove that the PET/MR scanner allows even multifunctional imaging with PET, functional MRI (fMRI) and spectroscopy," said Pichler, indicating this exciting work was made possible by a collaborative effort of researchers from the universities of Tennessee and Tuebingen (in Germany) and Siemens Medical Solutions. "PET/MR is an imaging technique that brings the exceptional soft tissue contrast and high specificity of MR together with PET's excellent sensitivity in assessing physiological and metabolic state," he added.

Combined or hybrid technologies—such as PET/CT and SPECT/CT—incorporate both imaging modalities into one machine but conduct the two scans sequentially (one after the other), explained Pichler. "This PET/MR machine—developed by Siemens and which debuted last year—acquires MR and PET scans at the same time, for the same imaging volume and, therefore, produces a higher degree of registration," he said. "The PET/MR system allows simultaneous measurement of anatomy, functionality and biochemistry of the body's tissues and cells, enabling researchers to correlate MR and PET data in a way not previously possible before," Pichler noted. "Neither the MR nor the PET imaging performance was degraded by synchronous data acquisition. The PET/MR data of the human brain revealed image qualities comparable to stand-alone systems without any significant distortions," he said.

Pichler explained some of the future possibilities with this PET/MR system. PET currently can differentiate mild cognitive impairment from early-stage Alzheimer's, but it cannot determine reduced brain volume caused by atrophy. "By combining MR and PET, clinicians may be able to make a more sound determination of both cognitive impairment and atrophy. Furthermore, combining PET/MR and new emerging neurological biomarkers has great potential to strengthen the assessment of the condition," said Pichler. Similarly, in stroke patients, the technology holds the promise of allowing doctors to study which brain tissues might be salvageable after a stroke.

PET imaging uses very small amounts of radioactive materials that are targeted to specific organs, bones or tissues. Radiotracers (such as FDG) are injected and then detected by a special type of camera that works with computers to provide precise pictures of the area of the body being imaged and molecular images of the body's biological functions. MRI uses radio waves and a strong magnetic field to provide clear and detailed pictures of internal organs and tissues. Functional MRI (fMRI) is a procedure that uses MR imaging to measure the quick, tiny metabolic changes that take place in an active part of the brain. Spectroscopy is a procedure that examines the biochemical constituents of a body part.

Siemens' PET/MR is a non-commercially available prototype dedicated brain PET scanner that is inserted into a commercial 3T MRI scanner. The prototype dedicated brain PET scanner uses a next-generation Avalanche Photodiode Detector technology. APD technology renders the PET scanner impervious to magnetic fields while providing excellent PET results.

###

Scientific Paper 152: H. Schlemmer, B.J. Pichler and C.D. Claussen, Department of Radiology, University of Tuebingen, Tuebingen, Germany; K. Wienhard, W. Heiss, Max-Planck-Institute for Brain Research, Cologne, Germany; M. Schmand, Siemens Medical Solutions, Knoxville, Tenn.; and C. Nahmias and D. Townsend, Department of Cancer Imaging and Tracer Development, University of Tennessee Medical Center, Knoxville, "Simultaneous MR/PET for Brain Imaging: First Patient Scans," SNM's 54th Annual Meeting, June 2–6, 2007.

About SNM—Advancing Molecular Imaging and Therapy

SNM is holding its 54th Annual Meeting June 2–6 at the Washington Convention Center in Washington, D.C. Session topics for the 2007 meeting include brain amyloid imaging, hybrid imaging, molecular imaging in clinical drug development and evaluation, functional brain imaging in epilepsy and dementia, imaging instrumentation, infection imaging, lymphoma and thyroid cancer, cardiac molecular imaging, general nuclear medicine, critical elements of care in radiopharmacy and more.

SNM is an international scientific and professional organization of more than 16,000 members dedicated to promoting the science, technology and practical applications of molecular and nuclear imaging to diagnose, manage and treat diseases in women, men and children. Founded more than 50 years ago, SNM continues to provide essential resources for health care practitioners and patients; publish the most prominent peer-reviewed journal in the field (the Journal of Nuclear Medicine); host the premier annual meeting for medical imaging; sponsor research grants, fellowships and awards; and train physicians, technologists, scientists, physicists, chemists and radiopharmacists in state-of-the-art imaging procedures and advances. SNM members have introduced—and continue to explore—biological and technological innovations in medicine that noninvasively investigate the molecular basis of diseases, benefiting countless generations of patients. SNM is based in Reston, Va.; additional information can be found online at http://www.snm.org.
__________________
You're alive. Do something. The directive in life, the moral imperative was so uncomplicated. It could be expressed in single words, not complete sentences. It sounded like this: Look. Listen. Choose. Act. ~~Barbara Hall

I long to accomplish a great and noble tasks, but it is my chief duty to accomplish humble tasks as though they were great and noble. The world is moved along, not only by the mighty shoves of its heroes, but also by the aggregate of the tiny pushes of each honest worker. ~~Helen Keller
Stitcher is offline   Reply With QuoteReply With Quote

advertisement
Reply


Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
extended molecular pathology and mitochondrial modifications before PD hallmarks olsen Parkinson's Disease 0 02-14-2007 11:07 PM
New Molecular Entities paula_w Parkinson's Disease 3 01-11-2007 07:57 PM


All times are GMT -5. The time now is 12:10 PM.

Powered by vBulletin • Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.

vBulletin Optimisation provided by vB Optimise v2.7.1 (Lite) - vBulletin Mods & Addons Copyright © 2024 DragonByte Technologies Ltd.
 

NeuroTalk Forums

Helping support those with neurological and related conditions.

 

The material on this site is for informational purposes only,
and is not a substitute for medical advice, diagnosis or treatment
provided by a qualified health care provider.


Always consult your doctor before trying anything you read here.